TQ-Tracer discharge measurement with tracer
Mobile flow measurement for water with an unknown cross-section profile - salt Tracer
Get product information here:
The discharge measurement is performed by using the proven tracer-dilution method. It can be deployed in turbulent rivers, creeks or waters for which data regarding the cross-section profile are not available.
As a tracer material salt is used. After insertion of a known amount of tracer material two conductivity probes are determining the discharge.
- Simple, mobile discharge measurement
- Reliable results even without knowledge and independent of the cross-section profile
- Suitable for fast-flowing, turbulent waters or where access is limited
- Environmentally friendly, harmless for water
- Discharge values immediately available
- Easy transmission of measurement data from the sensor to receiving device via Bluetooth
- Convenient receiving of data on laptop
- Real-time visualisation of measurement data
- User-friendly guidance through the measurement by the included software TQ-Commander
- Simultaneous measurement with up to four probes
- Tracer material: salt (NaCl)
- Probe type: conductivity probe
- Compact and convenient: complete equipment securely packed in two cases
General | ||
Mesasuring principle: | Tracer dilution method with instantaneous feed | |
Application: | Discharges up to 10 m³/s | |
TQ-Amp (measurement device with Bluetooth-transmission) | ||
Memory capacity: | none (data storage in the receiving device) | |
Tranmsission interval: | 1 sec | |
Data transfer: | Bluetooth class 1 (transmission range up to 100m) | |
Operating temperature: | -20...+60 °C | |
Protection: | IP66 | |
Energy supply: | 3x 1.5 V batteries, size AA or 3x 1.5 V / 2500 mAh NiMH batteries, size AA | |
Operation time: | 50 hrs (with 3x 2500 mAh batteries) | |
Charging time: | approx. 10 hrs | |
Sonde | ||
Sonde-type | conductivity probe | optical fluorescence probe |
Measurement range: | 0...5000 μS/cm | 0...50 μg/l (ppb) |
Resolution | 0.1 μS/cm | 0.05 μg/l (ppb) |
Operating temperature | -20...+60 °C | 0...+50 °C |
Other features | Integrated temperature compensation | Further types of probes for different tracer materials available upon request. |